Instruments |
Model & Specification |
Photo |
Field Emission Scanning Electron Microscope (FESEM) |
TESCAN MAIA3LMH resolution:0.7nm@15kV,1.0nm@1kV acceleration voltage:0.2-30 kV amplification: 4×~1,000,000 accessory:EDS and metal spraying |
|
X-Ray Diffractometor (XRD) |
Shimadzu XRD-6100 range:6°-148°, min step:0.0001° type:powder, film and any materials that are difficult to fix. |
|
FourierTransformInfraredSpectrometer(FTIR) |
Nicolet iS50 range:4000–400 cm-1 function:ATR, transmission, diffuse reflection and in situ infrared. |
|
IonChromatograph |
Thermo Scientific-Integrion function:It can determine the anion content in pure water, including F-, Cl-, Br-, SO42-, NO3-, PO43-,Li+, Na+, K+, Ca2+, Mg2+, NH4+ level:ppm |
|
Elemental Analysis |
ELEMENT function:Content analysis of non-metallic elements (including five elements C, H, N, S and O). range:C:0.03-20mg;H:0.03-3mg;N:0.03-2mg;S:0.03-6mg;O:0.03-2mg |
|
Full Range Chromatograph for Oil |
JAS,based on Agilent 7890 function:It can determine the distillation process of raw oil or product oil. |
|
Specific Surface Area and Porosity Analyzer |
McKiebel BELSORP-Max function: It can realize simultaneous measurement of microhole, three-station specific surface and mesoporous, and can test specific surface area (SSA) and aperture analysis (including pore volume, pore size distribution, average pore size, etc.). |
|
Chemical Adsorption Instrument |
Quantachrome-Autosorb-iQC-TPX function:dynamic chemical adsorption: TPD, TPR, TPO, pulse titration. |
|
Simultaneous TG-DSC Apparatus |
NETZSCH-STA449F5 function:simultaneously get the TGA and DSC signals of the samples at the room temperature to 1600℃. |
|
Optical Contact Angle Measuring Device |
KRÜSS-DSA100 function:it can measure the contact Angle between liquid solid, analyze solid surface free energy, measure the static contact Angle, Angle and back Angle, which can realize the constant temperature measurement from room temperature to 130℃. |
|
Atomic Absorption Spectrophotometer (AAS) |
Shimadzu AA-6880 function:it can measure the content of Fe、Mn、Na、Mg、K、Ca、Cu、Ag in aqueous solution. accuracy:ppm for flame method and ppb for graphite furnace method. |
|
Nano particle size and zeta potential analyzer |
Malvern Zetasizer Nano ZSE function:it can measure the particle size (0.3 nanometer to 10 micron), Zeta potential (mpt-2 multi-purpose three-part automatic titrator) and absolute molecular weight. |
|
Laser Particle Size Analyzer (LPSA) |
OMEC LS-909 Range:0.02~2100μm(wet process)、0.1~2100μm(dry process) |
|
Electrochemical Workstation |
Princeton- VersaStudio function:Volt-ampere technology, corrosion technology, energy technology and alternating current impedance technology |
|
Scanning Electrochemical Microscopy (SECM) |
Princeton VersaSCAN-VersaStat3 /3F Function: It can study the local electrochemical reactions, obtain the electrochemical parameters of each measured position and create a data schematic of local current by scanning the measurement probe. It can also study the volt-ampere technology, corrosion technology, energy technology and alternating current impedance technology |
|
Steady-state Surface Photovoltage Spectrometer |
CHF-XM-500W Function: Photovoltage measurement, photocurrent measurement, photovoltaic phase spectrum, photoelectric conversion efficiency (IPCE) |
|
On-line Gas Mass Spectrometers |
Pfeiffer-GSD32002OmniStar; TILON-LC-D200M Range: 1-200amu, Function: residual gas analysis (RGA), catalytic research (TPR, TPD, TPO), environmental exhaust analysis, gas purity analysis, reaction kinetics, etc. |
|
Vacuum Sputtering Plating Machine |
MSP-300B function:coating by direct current sputtering, radio frequency sputtering, oblique target co-sputtering and vertical sputtering. The target materials include Al, Cu, Ti and graphite. |
|
Slow Strain Rate Tensile Stress Corrosion Tester |
CRIMS MFDL100-100KN Max load:100KN; drawing rate:0.00000001/s~0.000001/s; Max travel of pull rod:180mm |
|
Electo-hydraulic Servocontrolled Fatigue Testing Machine |
CRIMS SDS100-100KN Maximum static test force :±100kN; Maximum dynamic test force:±80KN;Actuator effective travel :±50mm |
|
Highspeed Camera |
Japan-NAC Light source:Montedison Video light LED-V200; Lens:Nikon 24-85mm f/2.8-4D and Nikon 80-200mm f/2.8D; Spider:Manfrotto 475B; Holder:Manfrotto 808RC4 |
|